Respironics DS250HS REMstar Plus with humidifier, SD card, C-Flex
The Philips-Respironics "System One" REMstar takes a smarter approach to the entire sleep management process. The PR System One uses a SD card for data collection. Prior to the System One, patients were required to use a specialized card reader when uploading sleep data to a computer. Philips-Respironics has made this process easier by using the standard SD card, giving the patient the ability to use any SD reader to upload sleep data to the EncorePro or EncoreAnywhere software. The REMstar will record Patterns of use data only. System One Humidity Control (optional)
The PR CPAP humidifier and water chamber design are breakthroughs for managing rain-out and water damage. System One Humidity Control technology analyzes ambient temperature and patient airflow to reach relative humidity at the mask. Choose from 5 levels of relative humidity.
System One is the first humidifier in the industry which accounts for room humidity. Sensors inside and outside the CPAP machine closely monitor changes in humidity and prevents condensation from forming inside the tube.
Dry Box technology is another breakthrough in reducing water damage to the CPAP. Several unique designs are incorporated into the humidifier to prevent water from exiting the chamber. To start, the air outlet port has been moved from the side of the humidifier onto the top. This centers the entire delivery; minimizing the total water displacement around the hole. The water chamber is outfitted with one-way valve, between the machine and the humidifier. Any water that manages to escape the chamber gets trapped within the Dry Box, which acts as a reservoir for any water ingress past the valve.
System One and Dry Box Technology make it possible for the PR CPAP machines to be truly spill-free. This humidifier, even with a chamber filled to the "Full" indicator line, can be tilted, shaken, and even turned upside down without water leaking back into the device.
System One Resistance Control
Respironics wanted a machine to achieve optimal pressure no matter which mask is used. Resistance Control is the solution, a numbering system on all of Respironics CPAP masks based on variable resistance characteristics. Each number instructs the device to compensate for different mask types. The result? A consistent and reliable pressure enhanced with all the benefits of Flex Technology no matter which mask is used.
Flex Family Technology
Flex Technology is designed to enhance traditional CPAP therapy; maintaining effective therapy at minimal pressures. Users new to CPAP equipment find the Flex feature provides airflow at just the right pressure relief for every breath and makes adapting to CPAP therapy easier.
C-Flex offers a comfortable way to deliver sleep therapy by giving pressure relief at exhalation. Pressure is lowered based on a breath-per-breath analysis and provides up to 3 levels of relief based on the patient's expiratory flow.
Specifications
| 110 Voltage |
YES |
| 220 Voltage |
YES |
| Altitude Adjustment |
Manual |
| Can Use A Battery? |
YES |
| Data Card |
YES |
| Data Card Reading |
On-board: up to 6 months (Included) SD card: > 1 year |
| Dimensions |
7in L x 5.5in W x 4in. H |
| HCPCS Reimbursement Code |
E0601, A7037 |
| Heated Humidifier |
Optional |
| Included In Box |
CPAP machine, performance tubing, AC power cord, 2 filters, user manual, SD card, and carrying case. |
| Manufacturer |
Respironics |
| Mask Off Alert |
YES |
| Other Information |
Made in the USA |
| Prescription Required |
YES |
| Ramp |
0 to 45 min. (5 min. increments) |
| Weight |
3 LBS |
| Warranty |
2 year manufacturer |
| Pressure Range |
4-20 cm/H2O |
| Product Condition |
New |