Weight Operating Sound Level Pressure Range Water Chamber Capacity Warranty
1.56 lbs. 25.8 dBA 4 - 25 cmH2O 325 mL 2 Year Limited

DreamStation has a powerful suite of features to support your business and patients. Connecting patients and care teams, DreamStation is designed to increase patient acceptance and adherence while creating workplace efficiencies for you and your staff.


Patient driven design

A sleek, stylish, low-profile design offers the important features patients told us they wanted in a therapy device. It’s small and light, making it easy to pack for travel. It features easy-to-navigate menus, a front-facing display that can be operated while lying down or sitting up in bed as well as an easy-to-clean, one-piece humidifier water chamber.


Acclimation made easy

DreamStation includes a set of tools to help make it easy for patients starting PAP therapy and for their continued long-term use. EZ-Start can help patients gradually acclimate to therapy, while SmartRamp allows users to fall asleep to lower pressures.


Simplified device evaluation

Remote troubleshooting simplifies in-home device evaluation and can help reduce the number of normally functioning devices that are returned for service. Patients can use the easy device self-diagnostic tool to reduce the time and frustration associated with device troubleshooting.


Cost-effective connectivity options

Integrated Bluetooth® is standard on every device, and optional Wi-Fi and cellular modems provide the most comprehensive suite of connectivity options among leading CPAP brands.* DreamStation's modular design makes it easy for you to choose the most cost-effective option for each patient.


Support for the long term

Built-in Bluetooth makes connectivity to the DreamMapper patient self-management tool easy. DreamMapper provides goal-setting tools, helpful videos and ongoing feedback to keep patients motivated and engaged. Patients can get the help they need fast, without having to use your staff’s time to resolve.

Wake up to progress

Each morning patients are greeted with a summary of their progress to motivate them to stick with their therapy. The display shows a simple trend of their nightly hours of use, followed by a summary of the last 30 days of “good nights” that have more than 4 hours of use.


Connect to the care team

Connection to our powerful Encore Anywhere patient compliance management software provides a range of tools to monitor and manage your patients. Adherence Profiler is an optional, intuitive tool that helps you focus your staff’s time on the patients with the greatest likelihood of success.
Environmental
Operating Temperature: 5° to 35° C (41° to 95° F)
Storage Temperature: -20° to 60° C (-4° to 140° F)
Relative Humidity (operating & storage): 15 to 95% (non-condensing)
Atmospheric Pressure: 101 to 77 kPa (0 - 2286 m / 0 - 7500 ft)
Physical
Dimensions: 15.7 x 19.3 x 8.4 cm (6.2" L x 7.6" W x 3.3" H)
Weight (Device with power supply): Approximately 1.33 kg (2.94 lbs)
Service Life
The expected service life of the DreamStation Therapy Device and Link Module is 5 years.
Standards Compliance: This device is designed to conform to the following standards:
IEC 60601-1 General Requirements for Basic Safety and Essential Performance of Medical Electrical Equipment
ISO 80601-2-70 Sleep Apnea Breathing Therapy Equipment
EN 60601-1-2 Electromagnetic Compatibility
RTCA/DO-160G section 21, category M; Emission of Radio Frequency Energy
IEC 60601-1 Classification
Type of Protection Against Electric Shock: Class II Equipment
Degree of Protection Against Electric Shock: Type BF Applied Part
Degree of Protection against Ingress of Water: Device: Drip Proof, IP22 
Link Module: Drip Proof, IP22
80W power supply: Drip Proof, IP22
Mode of Operation: Continuous
Electrical
AC Power Consumption (with 80W power supply): 100 – 240 VAC, 50/60 Hz, 2.0-1.0 A
Note: Power supply is part of the medical electrical equipment.
DC Power Consumption: 12 VDC, 6.67 A
Fuses: There are no user-replaceable fuses.
Radio Specifications
Operating Frequency Range: 2402 - 2480 MHz
Maximum Output Power: 4.0 dBm
Modulation: GFSK, P/4 DQPSK, 8DQPSK
Intake Port Filters
Pollen Filter: 100% Polyester
88% Efficient @ 7-10 micron size
Ultra-fine Filter: Blended Synthetic Fiber
95% Efficient @ 0.5-0.7 micron size
Declared Dual-Number Noise Emissions Values In accordance with ISO 4871
The A-weighted sound pressure level is:
Device: 25.8 dB(A) with and uncertainty of 2 dB(A).
Device with Humidifier: 27.9 dB(A) with and uncertainty of 2 dB(A).
The A-weighted sound power level is:
Device: 33.8 dB(A) with an uncertainty of 2 dB(A).
Device with Humidifier: 35.9 dB(A) with an uncertainty of 2 dB(A).
Note: Values determined according to noise test code given in ISO 80601-2-70:2015, using the basic standards ISO 3744 and ISO 4871.
Pressure Accuracy
Pressure Increments: 4.0 to 20.0 cm H2O (in 0.5 cm H2O increments)
Maximum static pressure accuracy, according to ISO 80601-2-70:2015:
Pressure Static Accuracy
10 cm H2O ± 0.5 cm H2O
Static pressure accuracy has a measurement uncertainty of 1.20%
Maximum dynamic pressure variation, according to ISO 80601-2-70:2015:
Pressure 10 BPM 15 BPM 20 BPM
< 10 cm H2O ± 0.3 cm H2O ± 0.4 cm H2O ± 0.6 cm H2O
≥ 10.0 to 20 cm H2O ± 0.4 cm H2O ± 0.7 cm H2O ± 0.9 cm H2O
Dynamic pressure accuracy has a measurement uncertainty of 2.10%
Note: All tests were performed with and without humidifier and with both 22 mm standard tube and 15 mm heated tube.
Maximum Flow Rate (typical)
Test pressures (cm H2O)
4.0 8.0 12.0 16.0 20.0
22 mm
tubing
Measured pressure at the patient
connection port (cm H2O)
2.4 6.8 10.8 14.7 18.6
Average flow at the patient
connection port (l/min)
137.0 151.0 150.0 160.0 170.0
15 mm
tubing
(heated
or nonheated)
Measured pressure at the patient
connection port (cm H2O)
2.9 6.8 10.8 14.7 18.7
Average flow at the patient
connection port (l/min)
139.0 139.0 139.0 146.0 151.0

Limited Warranty

Respironics, Inc. warrants that the system shall be free from defects of workmanship and materials and will perform in accordance with the product specifications for a period of two (2) years from the date of sale by Respironics, Inc. to the dealer. If the product fails to perform in accordance with the product specifications, Respironics, Inc. will repair or replace – at its option – the defective material or part. Respironics, Inc. will pay customary freight charges from Respironics, Inc. to the dealer location only. This warranty does not cover damage caused by accident, misuse, abuse, alteration, water ingress, and other defects not related to material or workmanship. The Respironics, Inc. Service department shall examine any devices returned for service, and Respironics, Inc. reserves the right to charge an evaluation fee for any returned device as to which no problem is found after investigation by Respironics, Inc. Service.

This warranty is non-transferable by unauthorized distributors of Respironics, Inc. products and Respironics, Inc. reserves the right to charge dealers for warranty service of failed product not purchased directly from Respironics, Inc. or authorized distributors.

Respironics, Inc. disclaims all liability for economic loss, loss of profits, overhead, or consequential damages which may be claimed to arise from any sale or use of this product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty is given in lieu of all other express warranties. In addition, any implied warranties – including any warranty of merchantability or fitness for the particular purpose – are limited to two years. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

To exercise your rights under this warranty, contact your local authorized Respironics, Inc. dealer or contact Respironics, Inc. at:

1001 Murry Ridge Lane
Murrysville, Pennsylvania 15668-8550
1-724-387-4000

Our service area covers most of Southern California including Los Angeles and surrounding cities.
To see a full list of cities covered in our service area please .